IC660BBS102

GE Fanuc | Genius | GE Fanuc IC660 Genius PLC

IC660BBS102 Image

IC660BBS102

Same Day - Free Shipping

  • Manufacturer: GE Fanuc
  • Description: Ge Fanuc Block 115Vac/125Vdc Low Leak Isol I/O, w/Failed Sw Diag, 8 Ckt
  • Weight: 4 lbs :: ≈ 2 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC660BBS102 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -R1,

Product Manual Excerpt

115 VAC/125 VDC Isolated Genius I/O blocks have four isolated groups of two I/O circuits, each rated to operate at a nominal 115 volts AC or 125 volts DC. 115VAC/125VDC 8 Circuit Isolated I/O Blocks (IC660BBS102 and BBS100). These blocks report a Failed Switch diagnostic if any output s commanded state is not the same as the actual state of the block s own internal switch. 115 VAC/125VDC Isolated I/O Blocks without Failed Switch Diagnostic (IC660BBS103 and BBS101). For applications where field wiring such as manual switches will be wired in parallel with block outputs. These blocks ignore differences between an output s commanded state and the actual state of the block s internal switch. Isolation is rated to withstand 250 VAC/VDC continuous between any group and ground or between any two groups. Transient rating is 2000V peak for 10 sec. Control power for the block is tapped off the input/output device voltages wired to the terminals. The block has terminals for a separate power source for the internal electronics. The block power supply can be independently either AC or DC. The block need not be powered in the same manner as the circuits. Features Configurable features of these blocks include: AC/DC circuit voltage Output Pulse Test capability Selectable Input Filter Time from 10mS to 100mS Output powerup defaults Output Hold Last State or default CPU Redundancy type Bus Switching Module control 2A/Pt Max 15A Max Total 115V 50/60 Hz 125 VDC Isolated In/Out GE Fanuc GENIUS Electronic fusing is built into each circuit used as an output. The circuit is shut down 5mS after a short occurs. It can be easily restarted from a Hand held Monitor or from the CPU. The blocks perform these additional diagnostic checks: Overtemperature Open Wire for tristate inputs. Detection of loss of I/O power on pairs of circuits Overload Detection and Shutdown No Load Detection Inductive: for blocks BBS102 and BBS103 40 mA 10 mA Fusing 5 GEK-90486D-2 Chapter 5 115 VAC/125 VDC Isolated I/O Blocks 5-3 Compatibility Hand-held Monitor: These blocks are fully compatible with a Hand held Monitor identified by catalog number IC660HHM501. They may also be used with HHM500. HHM501 is required to change baud rate configuration, or to configure the block for redundancy. Bus Controller: The blocks may be used with any GE Fanuc Genius bus controller, PCIM or QBIM. I/O Blocks: These blocks are backward compatible with previous block versions (IC660CBS100, IC660BBS100, and IC660BBS101). They may be used as replacements for earlier versions. However, their Terminal Assemblies are not backward compatible, as explained below. Electronics Assembly: Electronics Assembly IC660EBS100H may be used to replace any Electronics Assembly IC660ELS100 or IC660EBS100. Electronics Assembly IC660EBS101C may be used to replace any version IC660ELS100, EBS100, or EBS101. These Electronics Assemblies draw lower leakage current (7mA) than earlier versions (which drew 13mA). Terminal Assembly: The Terminal Assembly for these blocks (IC660TSS100E) is not compatible with some earlier versions of their Electronics Assemblies (IC660EBS100A to G, or IC660EBS101A or B). If Terminal Assembly IC660TSS100E will be used to replace an earlier version of the Terminal Assembly, it will also be necessary to upgrade the Electronics Assembly. This can be done by replacing the entire Electronics Assembly with version IC660EBS100H or IC660EBS101C, or later. It can also be done by upgrading the Electronics Assembly firmware using one of these update kits: 44A286357 G06 (with Failed Switch Diagnostics) 44A286390 G03 (without Failed Switch Diagnostics) 5 5-4 Genius I/O Discrete and Analog Blocks User s Manual September 1993 GEK-90486D-2 Block Operation An Isolated block has four isolated groups of two I/O circuits, each rated to operate at a nominal 115VAC or 125VDC. Output Device couplers Circuit LEDs Each circuit has its own LED. If the circuit is configured as an input, the LED indicates the presence of threshold voltage at the input terminal. If the circuit is configured as an output, the LED indicates the state commanded by the CPU. Inputs and Outputs An Isolated Block can be configured as an inputs only, outputs only, or combination block. For a new block, the default is inputs only. Regardless, the block always broadcasts one byte of data each bus scan, and accepts one byte of data each bus scan. If the block is configured as a combination block, circuits can be any mix of inputs and/or outputs. The block will use 8 input references and 8 output references. The actual state of each output will be returned to the CPU in the corresponding input reference location. The CPU can monitor the feedback state to verify (after an appropriate delay) that the output switching device has operated properly and that the load has the proper voltage and current applied. If the block is configured as an inputs only block, all circuits must be regular inputs or tristate inputs. The block will use 8 input references and NO output references. If the block is configured as an outputs only block, all circuits must be be outputs; no feedback analysis will be performed. The block will use 8 output references and NO input references. Appendix B shows reference usage for a Series 90, Series Six, or Series Five PLC. 5 GEK-90486D-2 Chapter 5 115 VAC/125 VDC Isolated I/O Blocks 5-5 Input Data Format The block broadcasts 1 byte of input data each bus scan. 5 5-6 Genius I/O Discrete and Analog Blocks User s Manual September 1993 GEK-90486D-2 Diagnostics 115 VAC/125 VDC Isolated I/O blocks perform the following diagnostic checks. The block reports all faults to the Hand held Monitor, and takes appropriate corrective action. Individual circuits can be configured not to send diagnostic messages to the CPU if a fault occurs. If the CPU requests diagnostic information from the block using Read Diagnostic datagrams, the block returns current diagnostics for all circuits, including any with CPU fault reporting disabled. Loss of I/O Power Diagnostic An Isolated I/O block operates as long as power is supplied to terminals 5 and 6. The Loss of I/O Power diagnostic, which is unique to these blocks, indicates that one pair of circuits is disconnected from field power. If either circuit of the pair is an input, the block sets it to 0. If either circuit is an output, the block turns it off. The block automatically sends a Loss of I/O Power diagnostic message to the Hand held Monitor. However, the message is not sent to the CPU unless the block is Pulse Tested. The Unit OK LED does not blink. When I/O power is restored, the circuits begin operating as soon as power reaches the minimum level. If I/O power to the block itself is lost, the block cannot send diagnostic messages to the CPU. The bus controller responds as it would to any other loss of block condition. Overtemperature Diagnostic Each circuit has a built in thermal sensor. If the block s internal temperature exceeds 100C, the block sends an OVERTEMPERATURE message and turns off the circuit to protect its internal electronics. This diagnostic is always performed for both inputs and outputs. Short Circuit Diagnostic Automatic output diagnostic. Output circuits are always protected by a short circuit level sensor at the switching device. An output will turn off within several microseconds after the instantaneous current exceeds 25 amps at turn on, or 15 amps after 2 cycles AC or 10mS for DC. The block will try to restart the load; if several attempts are unsuccessful, the output circuit is forced off and the block sends a SHORT CIRCUIT message. To restore normal operation, the cause of the current surge must be removed, GEK-90486D-2 Chapter 5 115 VAC/125 VDC Isolated I/O Blocks 5-7 Failed Switch Diagnostic BOTH Isolated block versions will report Failed Switch diagnostics for internal faults independent of the output state, on both input and output configured circuits. Examples include loss of communications with the block s internal microprocessor and some internal power supply faults. Block version IC660BBS100 will also report this diagnostic if an output s switch state is not the same as its commanded state. The block sends a Failed Switch message identifying the failed circuit. The logic state of the circuit is set to OFF. When an output fault occurs, the actual condition of the output switch is not known. If the output switch has failed shorted (or closed). current flow is not interrupted when the block forces the output state OFF. Action external to the block must be taken to remedy the problem. The FAILED SWITCH message can alert personnel or cause program logic to be activated, possibly shutting off power to the block, I/O section, or process. Note False Failed Switch diagnostics may be reported if an external device like a manual switch is wired in parallel with an output. Even if fault reporting for the circuit is disabled, it will be necessary to clear each Failed Switch fault detected by the block. If the application requires such a configuration, block version IC660BBS101 (no Failed Switch diagnostic) should be used. Open Wire Diagnostic The block automatically performs this diagnostic on any circuit configured as a tristate input. It will detect an electrical (not mechanical) malfunction. In addition to being configured as a tristate input, the circuit must have a 5.1K ohm, 1/2 Watt or larger non inductive resistor installed across the actual dry contacts of the input device (such as across the field device terminals). a41547 60% 40% H N OPEN WIRE Tri-state Thresholds With the switch closed (ON state), the circuit senses the low source impedance. With the switch open (OFF state), the circuit senses the added resistance. If a wire is broken, cut or removed, impedance becomes very high. The block will transmit 0 as the state of the input, and send an OPEN WIRE message. Devices such as photo sensors, electronic high speed counters, instrumentation, fiber optic sensors, and similar electronic devices cannot be monitored for Open Wire conditions. Such devices should be set up as standard, not tristate, inputs. GE offers compatible input devices including a 5.1K ohm monitoring resistor with its line of General Purpose Control sensor devices. 5 5-8 Genius I/O Discrete and Analog Blocks User s Manual September 1993 GEK-90486D-2 No Load Diagnostic This optional diagnostic can be enabled or disabled for individual outputs. For a new block, outputs are configured to report No Load conditions. In this configuration, energizing the output activates a no load current level. If the load does not continuously draw 50mA from the output circuit, the block sends a NO LOAD message. Because this diagnostic monitors both current and voltage, a No Load condition may cause an HHM monitoring an operating block to display 0 for the circuit although there is voltage at the output and the circuit LED is on. This diagnostic should be disabled for circuits on which very small loads (small relays, transformers, or indicating lamps) will draw less than 50mA. Overload Shutdown Like No load reporting, this diagnostic is also optional for individual outputs on the block. In addition to the protection provided by the block s built in Short Circuit detection, Overload Shutdown provides further protection for output loads, field wiring, and switching devices. AC Output Overload For an AC output, overload occurs if a load exceeds 2.8 amps (2.0 amps RMS) continuously for 100mS. The block will turn the output off and send an OVERLOAD message if Overload Shutdown is enabled. TIME MSEC (1DIV = 1 CYCLE, 60HZ AC) a40646 SHORT CIRCUIT FAULT LEVEL 45 45 35 30 25 20 15 10 5 0 3A DESTRUCTIVE FUSE TYPICAL LOAD (SIZE 3 CONTACTOR) PEAK INPUT CURRENT (AMPS) ACTIVE ELECTRONIC PROTECTION MAXIMUM MINIMUM (2.8A) 2A RMS TURN ON OVERLOAD SHUTDOWN LEVEL (OPTIONAL) 5 GEK-90486D-2 Chapter 5 115 VAC/125 VDC Isolated I/O Blocks 5-9 DC Output Overload For a DC output, overload occurs if the output exceeds 2 amps continuously for 10mS after the initial 10mS turn on period. DC circuit protection is shown below. a41562 SHORT CIRCUIT FAULT LEVEL (MINIMUM) OVERLOAD SHUTDOWN LEVEL (MINIMUM) TURN ON OVERLOAD SHUTDOWN LEVEL (MAXIMUM) SHORT CIRCUIT FAULT LEVEL (MAXIMUM) Individual outputs can be configured not to shut off at this level or send the OVERLOAD message. These restrictions apply: 1. Maximum load current: 10 amps 2. RMS Maximum duty cycle: limit duty cycle so that: (load current) x (% ON) is less than 1.0 amp. 3. Maximum ON time: 1 minute 4. Maximum total current of all outputs ON at the same time is less than 15 amps. For example, a maximum 10 amp load can be pulsed at a 10% duty cycle, or up to 1 minute ON and 9 minutes OFF. Higher repetition rates can be used if the duty cycle is maintained. Exceeding the 10 amp limit may cause a short circuit fault to be generated. The duty cycle derating to an average of 1 amp output current and the ON time limit are necessary to avoid overheating due to the increased power dissipation in the block at these high currents. Exceeding these limits may cause an overtemperature fault

Need To Order A Specific Revision?

Give us a call at 1-800-360-6802 or 1-919-535-3180. We can help you with your Revision specific needs.


UPS Ground shipping is always FREE!


What is New Surplus?

These “New Surplus” units are a great cost saving alternative. This product is in the original manufacturer’s packaging with all sub-assemblies and documentation. Comes with a PLC Distribution Factory & Supply 3-year warranty.


UPS Ground shipping is always FREE!


What is Surplus New?

Surplus New - New unused and includes all sub-assemblies and documentation. Product may ship in manufacturer or PLC Distribution Factory & Supply packaging and includes a PLC Distribution Factory & Supply 3 Year Warranty.


UPS Ground shipping is always FREE!


What is Reconditioned?

Reconditioned products from PLC Distribution Factory & Supply are a cost-effective alternative to new and obsoleted PLC products. Every part is reconditioned down to the circuit board level. All parts are thoroughly inspected and hand-cleaned before being functionally tested in a fully configured system.


Our Reconditioned Products always come with a PLC Distribution Factory & Supply 2-Year Warranty.

UPS Ground shipping is always FREE!


110% PRICE MATCH GUARANTEE


We stand behind our prices with a 110% price match guarantee. If you buy a part from us and, within seven days of purchase, find that part advertised on an authorized distributor's website for less, simply contact us and give us a link to the lower advertised price and we'll refund you 110% of the difference between your purchase price and the advertised lower price. The part must be in-stock for immediate shipment and be in similar condition. All pricing must be displayed without signing in.

Repair Service


3-5 Days for most repairs. 24 hour repair upon request at no extra charge. If part is unrepairable, we will exchange with a working unit or return unrepaired.